AES-2id:2023 Purpose and Scope

|

TL;DR

AES-2id:2023 is an AES information document titled "Guidelines for the characterization of the impulse response of rooms." Unlike ISO standards, AES-2id is a recommended practice providing practical guidance on acquiring high-quality impulse responses. It covers excitation signal selection, source and receiver setup, signal processing (deconvolution, windowing, truncation), SNR verification, and file format recommendations. AES-2id complements ISO 3382-1 by providing implementation detail that the ISO standard leaves to the practitioner. It is widely referenced in audio engineering for system tuning, convolution reverb, and acoustic design verification.

Document Purpose

AES-2id:2023 provides practical guidelines for acquiring room impulse responses (RIRs) with sufficient quality for acoustic analysis, system alignment, and auralization. While ISO 3382-1 defines what parameters to extract from impulse responses and the minimum quality requirements, AES-2id explains how to actually perform the measurement with modern equipment.

Scope

The document covers the complete measurement workflow:

  1. Excitation signal selection and generation
  2. Source and receiver positioning and directivity
  3. Signal processing — deconvolution, windowing, truncation
  4. SNR verification and quality assessment
  5. Averaging and spatial sampling strategies
  6. File formats and metadata
  7. Common errors and how to avoid them

Relationship to Other Standards

AES-2id is not a formal international standard — it is an AES information document (recommended practice). It complements:

  • ISO 3382-1: Defines room acoustic parameters and minimum INR requirements, but provides limited measurement methodology
  • IEC 60268-16: Uses impulse responses to compute MTF and STI
  • ISO 18233: Application of new measurement methods in building and room acoustics

Key Recommendations

AES-2id recommends logarithmic swept sine as the preferred excitation signal due to its superior SNR and harmonic rejection capability. It provides specific guidance on sweep duration, sample rate, fade-in/out, and pre/post silence padding. For deconvolution, it recommends the Farina inverse filter method over simple spectral division.

Applications Beyond Room Acoustics

While primarily focused on room measurement, the techniques in AES-2id apply to any system impulse response measurement: loudspeaker characterization, electronic equipment testing, and system identification for live sound alignment. The SonaVyx impulse response tool follows AES-2id guidelines for sweep generation, deconvolution, and quality verification.

Who Uses AES-2id

Audio consultants, system integrators, acoustic designers, and researchers reference AES-2id for impulse response acquisition. The document is particularly useful for those building measurement systems or validating commercial measurement software against a known methodology.

Try It Now

Open this measurement tool in your browser — free, no download required.

Open Tool

Last updated: March 19, 2026