Measurement Accuracy & Uncertainty
Accuracy describes closeness to truth; repeatability describes consistency. Understanding uncertainty sources produces reliable measurements supporting engineering decisions and regulatory compliance per the GUM framework.
Instrument
IEC 61672: ±1.1 dB Class 1, ±1.4 Class 2 at reference. Total: ±1.5/±2.5 dB root-sum-square across range.
Environmental
Temperature: ±0.6 m/s per degree C sound speed. Mic: ±0.01 dB/degree C. Wind: turbulent pressure. Humidity affects above 4 kHz.
Spatial
RT60 varies 5-15% across positions. ISO 3382-1 addresses via spatial averaging. Single-position overstates certainty.
Reducing
Calibrate, windscreen, record conditions, average multiple positions. Report method and conditions for transparency.
Budget
Per GUM. Expanded uncertainty (95%): ±2 dB lab, ±5 dB field.