ISO 3382-2: Acoustics — Measurement of room acoustic parameters — Part 2: Reverberation time in ordinary rooms
Acoustics — Measurement of room acoustic parameters — Part 2: Reverberation time in ordinary rooms
Specifies methods for measuring reverberation time in furnished ordinary rooms using the interrupted noise method or integrated impulse response method.
Key Clauses
| Clause | Title | Summary |
|---|---|---|
| 4.2 | Source requirements | Omnidirectional sound source, sufficient power for adequate SNR. |
| 4.3 | Microphone positions | Minimum distances from walls and between positions. |
| 5.3 | Evaluation | T20 or T30 from backward-integrated decay curve. |
| 6 | Uncertainty | Repeatability and reproducibility of measurements. |