RT60 Measurement — T20, T30 & EDT per ISO 3382-1
RT60 is the time for sound to decay 60 dB. ISO 3382-1 defines three extraction methods from the Schroeder decay curve: T20 (from -5 to -25 dB), T30 (from -5 to -35 dB), and EDT (from 0 to -10 dB), each requiring specific impulse-to-noise ratios for valid extraction.
Schroeder Backward Integration
ISO 3382-1 uses backward integration of the squared impulse response for a smooth decay curve equivalent to the ensemble average of many noise decays. This enables reliable extraction from a single measurement.
T20
Evaluates -5 to -25 dB decay, requires 35 dB INR per clause C.6. Useful when noise limits the usable range. The extrapolation assumes constant rate below -25 dB, which may not hold in coupled volumes.
T30
Uses -5 to -35 dB, requires 45 dB INR. Preferred metric: evaluates more of the decay. R-squared of linear regression must exceed 0.995 per Annex A for valid extraction.
EDT
Measures first 10 dB (0 to -10 dB). Correlates better with perceived reverberance. When EDT differs from T30, early reflections create a different impression than the physical decay rate indicates.
Octave Bands
RT60 varies across frequency. Low frequencies typically decay longer. Report in bands 125 Hz to 4 kHz. The mid-frequency average (500 + 1000 Hz) is the common single-number descriptor.
Try It Now